LH Power Running Board position (Hall Effect) sensor — Signal Invalid
Land Rover · body
Fiabilité de la donnée95%
The L405 Deployable Side Step ECU detected lh power running board position (hall effect) sensor with failure type 29, signal invalid. This interpretation is limited to the documented DSS controller.
Vérifications recommandées
Perform a full module scan
Verify battery voltage
Inspect DSS wiring and connectors
Inspect the running-board mechanism for binding
Check the Hall-effect sensor signal when applicable
Follow the Land Rover DSS troubleshooting guide
S'applique àRange Rover L405 2013 model yearDeployable Side Step (DSS) ECU
C1008:3A
LH Power Running Board position (Hall Effect) sensor Incorrect has too many pulses has sent too many pulses — Incorrect Signal Has Too Many Pulses
Land Rover · body
Fiabilité de la donnée95%
The L405 Deployable Side Step ECU detected lh power running board position (hall effect) sensor incorrect has too many pulses has sent too many pulses with failure type 3A, incorrect signal has too many pulses. This interpretation is limited to the documented DSS controller.
Vérifications recommandées
Perform a full module scan
Verify battery voltage
Inspect DSS wiring and connectors
Inspect the running-board mechanism for binding
Check the Hall-effect sensor signal when applicable
Follow the Land Rover DSS troubleshooting guide
S'applique àRange Rover L405 2013 model yearDeployable Side Step (DSS) ECU
C1008:93
LH Power Running Board position (Hall Effect) sensor — No Operation
Land Rover · body
Fiabilité de la donnée95%
The L405 Deployable Side Step ECU detected lh power running board position (hall effect) sensor with failure type 93, no operation. This interpretation is limited to the documented DSS controller.
Vérifications recommandées
Perform a full module scan
Verify battery voltage
Inspect DSS wiring and connectors
Inspect the running-board mechanism for binding
Check the Hall-effect sensor signal when applicable
Follow the Land Rover DSS troubleshooting guide
S'applique àRange Rover L405 2013 model yearDeployable Side Step (DSS) ECU
Plage définie par le constructeur : la signification peut varier selon les marques.
008
Index de défaut spécifique dans le sous-système.
Questions fréquentes sur C1008
Que signifie C1008 ?
Code défaut de diagnostic (3 variantes). The L405 Deployable Side Step ECU detected lh power running board position (hall effect) sensor with failure type 29, signal invalid. This interpretation is limited to the documented DSS controller.
C1008 est-il générique ou spécifique au constructeur ?
C1008 est un code spécifique au constructeur. Dans cette base il est documenté pour : Land Rover. Le même numéro peut signifier autre chose sur d'autres marques.
TuningBot peut-il supprimer C1008 au niveau du fichier ?
Non garanti. Les codes powertrain (P) se désactivent de façon fiable dans la calibration, mais les codes carrosserie, châssis et réseau dépendent du calculateur et de la façon dont le défaut est implémenté - certains sont traitables, d'autres non. Demandez un devis et nos ingénieurs examineront votre fichier et vous diront gratuitement si C1008 est supprimable dans votre cas.