LH Power Running Board position (Hall Effect) sensor — Signal Invalid
Land Rover · body
Достоверность данных95%
The L405 Deployable Side Step ECU detected lh power running board position (hall effect) sensor with failure type 29, signal invalid. This interpretation is limited to the documented DSS controller.
Рекомендуемые проверки
Perform a full module scan
Verify battery voltage
Inspect DSS wiring and connectors
Inspect the running-board mechanism for binding
Check the Hall-effect sensor signal when applicable
Follow the Land Rover DSS troubleshooting guide
Применимо кRange Rover L405 2013 model yearDeployable Side Step (DSS) ECU
C1008:3A
LH Power Running Board position (Hall Effect) sensor Incorrect has too many pulses has sent too many pulses — Incorrect Signal Has Too Many Pulses
Land Rover · body
Достоверность данных95%
The L405 Deployable Side Step ECU detected lh power running board position (hall effect) sensor incorrect has too many pulses has sent too many pulses with failure type 3A, incorrect signal has too many pulses. This interpretation is limited to the documented DSS controller.
Рекомендуемые проверки
Perform a full module scan
Verify battery voltage
Inspect DSS wiring and connectors
Inspect the running-board mechanism for binding
Check the Hall-effect sensor signal when applicable
Follow the Land Rover DSS troubleshooting guide
Применимо кRange Rover L405 2013 model yearDeployable Side Step (DSS) ECU
C1008:93
LH Power Running Board position (Hall Effect) sensor — No Operation
Land Rover · body
Достоверность данных95%
The L405 Deployable Side Step ECU detected lh power running board position (hall effect) sensor with failure type 93, no operation. This interpretation is limited to the documented DSS controller.
Рекомендуемые проверки
Perform a full module scan
Verify battery voltage
Inspect DSS wiring and connectors
Inspect the running-board mechanism for binding
Check the Hall-effect sensor signal when applicable
Follow the Land Rover DSS troubleshooting guide
Применимо кRange Rover L405 2013 model yearDeployable Side Step (DSS) ECU
Диапазон, заданный производителем: значение может отличаться у разных марок.
008
Конкретный индекс неисправности внутри подсистемы.
Частые вопросы о C1008
Что означает C1008?
Диагностический код неисправности (3 вариантов). The L405 Deployable Side Step ECU detected lh power running board position (hall effect) sensor with failure type 29, signal invalid. This interpretation is limited to the documented DSS controller.
C1008 — общий код или специфичный для производителя?
C1008 — код конкретного производителя. В этой базе он описан для: Land Rover. Тот же номер у других марок может означать другое.
Может ли TuningBot удалить C1008 на уровне файла?
Не гарантируется. Коды powertrain (P) надёжно отключаются в калибровке ЭБУ, а коды кузова, шасси и сети зависят от конкретного блока и реализации неисправности: часть решается, часть нет. Запросите расчёт — наши инженеры проверят файл и бесплатно скажут, удаляется ли C1008 в вашем случае.