LH Power Running Board position (Hall Effect) sensor — Signal Invalid
Land Rover · body
Affidabilità del dato95%
The L405 Deployable Side Step ECU detected lh power running board position (hall effect) sensor with failure type 29, signal invalid. This interpretation is limited to the documented DSS controller.
Controlli consigliati
Perform a full module scan
Verify battery voltage
Inspect DSS wiring and connectors
Inspect the running-board mechanism for binding
Check the Hall-effect sensor signal when applicable
Follow the Land Rover DSS troubleshooting guide
Si applica aRange Rover L405 2013 model yearDeployable Side Step (DSS) ECU
C1008:3A
LH Power Running Board position (Hall Effect) sensor Incorrect has too many pulses has sent too many pulses — Incorrect Signal Has Too Many Pulses
Land Rover · body
Affidabilità del dato95%
The L405 Deployable Side Step ECU detected lh power running board position (hall effect) sensor incorrect has too many pulses has sent too many pulses with failure type 3A, incorrect signal has too many pulses. This interpretation is limited to the documented DSS controller.
Controlli consigliati
Perform a full module scan
Verify battery voltage
Inspect DSS wiring and connectors
Inspect the running-board mechanism for binding
Check the Hall-effect sensor signal when applicable
Follow the Land Rover DSS troubleshooting guide
Si applica aRange Rover L405 2013 model yearDeployable Side Step (DSS) ECU
C1008:93
LH Power Running Board position (Hall Effect) sensor — No Operation
Land Rover · body
Affidabilità del dato95%
The L405 Deployable Side Step ECU detected lh power running board position (hall effect) sensor with failure type 93, no operation. This interpretation is limited to the documented DSS controller.
Controlli consigliati
Perform a full module scan
Verify battery voltage
Inspect DSS wiring and connectors
Inspect the running-board mechanism for binding
Check the Hall-effect sensor signal when applicable
Follow the Land Rover DSS troubleshooting guide
Si applica aRange Rover L405 2013 model yearDeployable Side Step (DSS) ECU
Gamma definita dal costruttore: il significato può cambiare tra marche.
008
Indice specifico del guasto dentro il sottosistema.
Domande frequenti su C1008
Cosa significa C1008?
Codice di errore diagnostico (3 varianti). The L405 Deployable Side Step ECU detected lh power running board position (hall effect) sensor with failure type 29, signal invalid. This interpretation is limited to the documented DSS controller.
C1008 è generico o specifico del costruttore?
C1008 è un codice specifico del costruttore. In questo database è documentato per: Land Rover. Lo stesso numero può significare altro su altre marche.
TuningBot può rimuovere C1008 a livello di file?
Non garantito. I codici powertrain (P) si disattivano in modo affidabile nella calibrazione della ECU, ma i codici body, telaio e rete dipendono dalla centralina e da come è implementato il guasto: alcuni si gestiscono, altri no. Chiedi un preventivo e i nostri ingegneri controlleranno il file e ti diranno gratuitamente se C1008 è rimovibile nel tuo caso.