RH Power Running Board motor line short to ground — Circuit Short to Ground
Land Rover · body
Fiabilité de la donnée95%
The L405 Deployable Side Step ECU detected rh power running board motor line short to ground with failure type 11, circuit short to ground. This interpretation is limited to the documented DSS controller.
Vérifications recommandées
Perform a full module scan
Verify battery voltage
Inspect DSS wiring and connectors
Inspect the running-board mechanism for binding
Check the Hall-effect sensor signal when applicable
Follow the Land Rover DSS troubleshooting guide
S'applique àRange Rover L405 2013 model yearDeployable Side Step (DSS) ECU
C1007:12
RH Power Running Board motor line short to battery — Circuit Short to Battery
Land Rover · body
Fiabilité de la donnée95%
The L405 Deployable Side Step ECU detected rh power running board motor line short to battery with failure type 12, circuit short to battery. This interpretation is limited to the documented DSS controller.
Vérifications recommandées
Perform a full module scan
Verify battery voltage
Inspect DSS wiring and connectors
Inspect the running-board mechanism for binding
Check the Hall-effect sensor signal when applicable
Follow the Land Rover DSS troubleshooting guide
S'applique àRange Rover L405 2013 model yearDeployable Side Step (DSS) ECU
C1007:13
RH Power Running Board motor line open — Circuit Open
Land Rover · body
Fiabilité de la donnée95%
The L405 Deployable Side Step ECU detected rh power running board motor line open with failure type 13, circuit open. This interpretation is limited to the documented DSS controller.
Vérifications recommandées
Perform a full module scan
Verify battery voltage
Inspect DSS wiring and connectors
Inspect the running-board mechanism for binding
Check the Hall-effect sensor signal when applicable
Follow the Land Rover DSS troubleshooting guide
S'applique àRange Rover L405 2013 model yearDeployable Side Step (DSS) ECU
C1007:19
RH Power running board motor short — Circuit Current Above Threshold
Land Rover · body
Fiabilité de la donnée95%
The L405 Deployable Side Step ECU detected rh power running board motor short with failure type 19, circuit current above threshold. This interpretation is limited to the documented DSS controller.
Vérifications recommandées
Perform a full module scan
Verify battery voltage
Inspect DSS wiring and connectors
Inspect the running-board mechanism for binding
Check the Hall-effect sensor signal when applicable
Follow the Land Rover DSS troubleshooting guide
S'applique àRange Rover L405 2013 model yearDeployable Side Step (DSS) ECU
C1007:67
RH Power running board motor current sensing — Signal Incorrect After Event
Land Rover · body
Fiabilité de la donnée95%
The L405 Deployable Side Step ECU detected rh power running board motor current sensing with failure type 67, signal incorrect after event. This interpretation is limited to the documented DSS controller.
Vérifications recommandées
Perform a full module scan
Verify battery voltage
Inspect DSS wiring and connectors
Inspect the running-board mechanism for binding
Check the Hall-effect sensor signal when applicable
Follow the Land Rover DSS troubleshooting guide
S'applique àRange Rover L405 2013 model yearDeployable Side Step (DSS) ECU
Plage définie par le constructeur : la signification peut varier selon les marques.
007
Index de défaut spécifique dans le sous-système.
Questions fréquentes sur C1007
Que signifie C1007 ?
Code défaut de diagnostic (5 variantes). The L405 Deployable Side Step ECU detected rh power running board motor line short to ground with failure type 11, circuit short to ground. This interpretation is limited to the documented DSS controller.
C1007 est-il générique ou spécifique au constructeur ?
C1007 est un code spécifique au constructeur. Dans cette base il est documenté pour : Land Rover. Le même numéro peut signifier autre chose sur d'autres marques.
TuningBot peut-il supprimer C1007 au niveau du fichier ?
Non garanti. Les codes powertrain (P) se désactivent de façon fiable dans la calibration, mais les codes carrosserie, châssis et réseau dépendent du calculateur et de la façon dont le défaut est implémenté - certains sont traitables, d'autres non. Demandez un devis et nos ingénieurs examineront votre fichier et vous diront gratuitement si C1007 est supprimable dans votre cas.