NOx sensors enable closed-loop control of SCR systems and provide emissions monitoring for diagnostics.
Sensor Locations
- Upstream — measures engine-out NOx for dosing calculation
- Downstream — verifies SCR conversion efficiency
Efficiency Monitoring
Conversion = (Upstream - Downstream) / Upstream × 100%
Target efficiency: 85-98% depending on conditions.